Frankonia FAC-3 L Fully Anechoic 3m EMC Chamber for floor-standing EUT’s
Overview | FAC-3 L |
EMI | CISPR 16-1-4 and IEC/EN 61000-4-22, full compliant |
EMS | IEC/EN 61000-4-3 and IEC/EN 61000-4-22, full compliant |
Test distance | 3m |
Volume | ø1,5 m (H=2,0 m) |
Special | Free-space test environment for table-top and floor-standing EUT’s |
The FAC-3 L is the extended version of Frankonia’s fully anechoic chamber solution at 3,0m measuring distance for EMC tests on table top positioned EUT’s as well as on floor-standing EUT’s. It is designed as full compliant chamber for measurements under free-space conditions and is based on CISPR 16-1-4 as a test site without ground plane. Without the reflections from the floor, a height scan is no longer necessary. With its specific requirements for the test site, Frankonia’s FAC-3 is supremely prepared to meet our customers’ demands.
Features
• Test site for table top and floor-standing EUT’s
• Full compliant EMI/EMS
• Cost effective solution for free-space measurements
• Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
• Turnkey solution
Typical Product Standards
Emission
• CISPR 14
• CISPR 32
• ETSI
Immunity
• IEC/EN 61000-4-3
Typical Verification Standards
Emission
• CISPR 16-1-4
• IEC/EN 61000-4-22
Immunity
• IEC/EN 61000-4-3
• IEC/EN 61000-4-22
TYPICAL SPECIFICATIONS
Chamber | FAC-3 L |
External dimensions | 9.380 x 5.780 x 5.550 mm (LxWxH) |
Quiet Zone | ø1,5 m (H=2,0 m); floor standing EUT tests |
Turntable | ø1,5 m |
Measuring distances | 3,0 m |
Load capacity | up to 2,0 tons; special turntable systems possible |
Frequency range | 9 kHz/ 30 MHz to 18 GHz (option 40 GHz) |
Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4
Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard
Deviation SdB c ≤ 1,8 dB