חיפוש
סגור את תיבת החיפוש

FRANKONIA – SAC-10 PLUS SEMI ANECHOIC EMC CHAMBER

Frankonia SAC-10 Plus Semi Anechoic 10m EMC Chamber in Compact shape

Overview Frankonia SAC-10 Plus
EMI CISPR 16-1-4 and ANSI C63.4, full compliant
EMS IEC/EN 61000-4-3, full compliant
Test distance 3,0 m, 5,0 m and 10,0 m
Volume up tp ø3,0 m
Special Compact 10 m chamber

The SAC-10 Plus is Frankonia’s full compliant and state-of-the-art EMC testing solution at 10m, 5m & 3m measuring distances with a Quiet Zone (QZ) of ø4,0m. The innovative polygonal shape along with its optimized absorber layout is a space-saving, cost-saving and efficient solution with a single test axis. The SAC-10 Plus is fully compliant for emission tests validated according to CISPR 16-1-4, as well as full compliant for immunity tests according to IEC/EN 61000-4-3. In addition, the SAC-10 Plus is Frankonia’s most compact 10m chamber available to meet CISPR 16-1-4 and ANSI C63.4 test site requirements.

 

Features

• 10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m or ø4,0 m

• Full compliant EMI/EMS

• Ingenious absorber lining with Frankosorb®

• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

• Cost-saving and future-proof investment Space-saving chamber in polygonal shape

• Turnkey solution

Typical Product Standards

Emission

• CISPR 11

• CISPR 14

• CISPR 15

• CISPR 25

• CISPR 32

• MIL-STD 461

Immunity

• IEC/EN 61000-4-3

• ISO 11452

• MIL-STD 461

Typical Verification Standards

Emission

• CISPR 16-1-4 and/or ANSI C63.4

Immunity

• IEC/EN 61000-4-3

Typical Specifications

Chamber SAC-10 Plus
External dimensions 19.205 x 12.080 x 8.325 mm (LxWxH)
Version Polygonal shape design with single test axis
Quiet Zone ø3,0 m or ø4,0 m
Turntable ø3,0 m or ø4,0 m
Measuring distances 10,0 m, 5,0 m and 3,0 m
Load capacity up to 5,0 tons; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Interfaces for Franikonia Anechoic Chambers Data Sheet