Frankonia SAC-10 Plus Triton Semi Anechoic 10m EMC Chamber with Multi-axes
Overview | SAC-10 Plus Triton |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0 m, 5,0 m and 10,0 m |
Volume | up tp ø3,0 m |
Special | Multi-axes 10m chamber |
The SAC-10 Plus Triton is Frankonia’s most modern and fully compliant EMC testing solution with a Quiet Zone of 3,0 m.
The innovative shape with its optimized absorber layout allows for a use of three axes having a ready test setup for emission and immunity tests.
The Triton is designed for test labs, that….
The Triton is the perfect test laboratory for service providers, research institutes and product developments, and for all who value efficiency and flexibility in operating an EMC lab.
The Triton is the state-of-the-art EMC test laboratory that allows an efficient use, reduces costs and time and ensures a stable quality and performance level. Lined with Frankosorb® absorbers generating reproducible results, the Triton guarantees a future-proof solution for any kind of EMI/EMS testing at the highest level.
Frankonia’s SAC-10 Plus Triton is a revolution in EMC testing that shifts the focus to simplify the testing procedures for engineers and institutes and holistically improves the efficiency of your EMC lab.
Stable Conditions
With its long-term performance Frankosorb® Absorbers, Frankonia guarantees a constant performance level of the validated SAC-10 Plus chamber for 10 years.
Only Frankosorb® absorbers guarantee your investment on the long-term.
The Triton is a future-proof solution that is fully flexible for any EMI and EMS test procedures, either following the conception of the three test axes, or adapted to your own test procedure.
Features
• Multiple test axis option (1x 10,0m and 2x 3,0m distance)
• 10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m
• Full compliant EMI/EMS
• No need to modify the test environment or the test setup
• Floor absorbers remain in the chamber with guided movements
• Antennas remain in the chamber
• Quality of testing at a constant high level
• Test time decreases considerably
• Excellent performance in a compact chamber size
• Ingenious absorber lining with Frankosorb®
• Cost-saving and future-proof investment
• Space-saving chamber in polygonal shape
• Easy and efficient to use
• Malfunctions or damages are almost impossible
• Optimized workflow
• Turnkey solution
Typical Product Standards
Emission
• CISPR 11
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11452
• MIL-STD 461
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
Immunity
• IEC/EN 61000-4-3
Typical Specifications
Chamber | SAC-10 Plus Triton |
External dimensions | 19.205 x 12.080 x 8.325 mm (LxWxH) |
Version | Polygonal shape design with multiple test axis |
Quiet Zone | ø3,0 m |
Turntable | ø3,0 m or ø4,0 m |
Measuring distances | Test axis 1: 10,0 m, 5,0 m and 3,0 m (for emission)
Test axis 2: 3,0 m (for emission and immunity) Test axis 3: 3,0 m (for immunity) |
Load capacity | up to 5,0 tons; special turntable systems possible |
Frequency range | 9 kHz/ 30 MHz to 18 GHz (option 40 GHz) |
Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed