חיפוש
סגור את תיבת החיפוש

FRANKONIA – SAC-10P PYRAMID SEMI ANECHOIC CHAMBER

Frankonia SAC-10/P Pyramid Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers

Overview SAC-10/P Pyramid
EMI CISPR 16-1-4 and ANSI C63.4, full compliant
EMS IEC/EN 61000-4-3, full compliant
Test distance up to 10,0m
Volume ø3,0 m up to ø6,0 m
Special P2400 Long-pyramid Absorbers

The SAC-10/P chambers are Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance offering various sizes of the Quiet Zone (QZ). Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emission and immunity testing.

Features

• Unique Frankosorb® P2400 Pyramid Absorbers

• Full compliant EMI/EMS

• Highly customizable solution for any kind of EMC testing and limitless integration of individual applications

• Adjustable chamber size, characteristics and configuration due to different EUT requirements

• Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)

• Specialized for ‘out-of-the-range’ EMC test environments

• Turnkey solution

Typical Product Standards

Emission

• CISPR 11

• CISPR 12

• CISPR 14

• CISPR 15

• CISPR 25

• CISPR 32

• MIL-STD 461

Immunity

• IEC/EN 61000-4-3

• ISO 11451

• ISO 11452

• MIL-STD 461

• RS 101, RS102, RS103

Typical Verification Standards

Emission

• CISPR 16-1-4 and/or ANSI C63.4

Immunity

• IEC/EN 61000-4-3

Typicl Specifications

 

Chamber Type

SAC-10-3/P

SAC-10-4/P

SAC-10-5/P

SAC-10-6/P

External dimension

21.680 x 13.730 x 8.550 mm (LxWxH)

21.680 x 13.730 x 8.550 mm (LxWxH)

23.480 x 16.580 x 9.000 mm (LxWxH)

24.980 x 17.180 x 9.000 mm (LxWxH)

Quiet Zone at 3,0m

ø3,0 m

ø3,0 m

ø3,0 m

ø3,0 m

Quiet Zone at 5,0m

ø3,0 m

ø4,0 m

ø5,0 m

ø5,0 m

Quiet Zone at 10,0m

ø3,0 m

ø4,0 m

ø5,0 m

ø6,0 m

Load capacity

up to 80,0 tons; special turntable systems and dynamometer integration possible

Frequency range

9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Interfaces for Franikonia Anechoic Chambers Data Sheet