חיפוש
סגור את תיבת החיפוש

FRANKONIA – SAC-3 PLUS SEMI 3M EMC CHAMBER

Frankonia SAC-3 Plus

Semi Anechoic 3m EMC Chamber with dome-shape design

Overview SAC-3 Plus
EMI CISPR 16-1-4 and ANSI C63.4, full compliant
EMS IEC/EN 61000-4-3, full compliant
Test distance 3m
Volume up to ø2,0 m
Special Performance dome shape design

The SAC-3 Plus is Frankonia’s most versatile full compliant EMC testing solution at 3,0 m measuring distance with a Quiet Zone (QZ) up to ø2,0 m. It is adapted for full compliant emission and immunity testing. The innovatively shaped roof, called dome design, with its optimized absorber layout leads to minimized reflections and offers outstanding performance for NSA, SVSWR and FU.

 

Features

• Cost-efficient and high-performance solution for a 3,0 m measuring distance

• Full compliant EMI/EMS

• Adapted steel structure and optimized RF-shielding with dome-shaped roof

• Upgradeable for E-Drive (load machine, BlueBox, battery test system)

• Ingenious absorber lining with Frankosorb®

• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

• Turnkey solution

Typical Product Standards

Emission

• CISPR 11

• CISPR 14

• CISPR 15

• CISPR 25

• CISPR 32

• MIL-STD 461

Immunity

• IEC/EN 61000-4-3

• ISO 11452

• MIL-STD 461

Typical Verification Standards

Emission

• CISPR 16-1-4 and/or ANSI C63.4

• IEC/EN 61000-4-3

Immunity

• IEC/EN 61000-4-3

Typical Specifications

Chamber Type

SAC-3 Plus S

SAC-3 Plus M

SAC-3 Plus L

SAC-3 Plus

External dimension

8.480 x 6.530 x 6.000 mm (LxWxH)

8.780 x 6.530 x 6.000 mm (LxWxH)

9.230 x 6.530 x 6.000 mm (LxWxH)

9.680 x 6.530 x 6.000 mm (LxWxH)

Quiet Zone

ø1,2 m

ø1,5 m

ø2,0 m

ø2,0 m

Load capacity

up to 5,0 tons; special turntable systems possible

Frequency range

9 kHz/ 26 MHz to 18 GHz (option 40 GHz)

 

Performance & Compliance – Semi Configuration

• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed