Frankonia SAC-5 Square Semi Anechoic 5m EMC Chamber with traditional square design
Overview | SAC-5 Square |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 5,0 m & 3,0 m |
Volume | up tp ø3,0 m |
Special | Traditional square design |
The SAC-5 Square is Frankonia’s full compliant EMC testing solution at 5,0 m measuring distance with a Quiet Zone (QZ) up to ø3,0 m. It is adapted for full compliant emission and immunity testing with a traditional square design.
Features
• Cost-efficient and high-performance solution for a 5,0 m measuring distance
• Full compliant EMI/EMS
• Adapted steel structure and optimized RF-shielding with traditional rectangular design
• Upgradeable for E-Drive (load machine, BlueBox, battery test system)
• Ingenious absorber lining with Frankosorb®
• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers
• Turnkey solution
Typical Product Standards
Emission
• CISPR 11
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11452
• MIL-STD 461
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
Immunity
• IEC/EN 61000-4-3
Typical Specifications
Chamber | SAC-5 Square |
External dimensions | 12.680 x 8.180 x 6.000 mm (LxWxH) |
Quiet Zone | ø3,0 m |
Measuring distances | 5,0 m and 3,0 m |
Load capacity | up to 5,0 tons; special turntable systems possible |
Frequency range | 9 kHz/ 26 MHz to 18 GHz (option 40 GHz) |
Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed