חיפוש
סגור את תיבת החיפוש

חברת מונטנה

ניווט מהיר:

חברת דולב הינה הנציגה הבלעדית של חברת מונטנה בישראל

Montena has been incorporated in 1903 as capacitor manufacturing company.

In 1978, the montena EMC division was created to address the arising EMC related problems.
Since then montena has earned a worldwide reputation for its leading-edge skills in the fields of high voltage,high frequency and electromagnetic fields.

Montena can count on highly specialized know-how in the field of the electromagnetic compatibility.

These skills are put to good use in the development and construction of various kinds of equipment,
especially EMC test equipment and fast electrical pulse generator.

Montena designs, builds and markets equipment and accessories for EMC tests.
The range of products includes antennas, TEM cells, striplines, field sensors,
all kind of pulse generators, test benches, etc.

Montena's high voltage pulse generators are mainly used for EMC tests,
high speed imaging and pulsed light decontamination.
Montena also builds pulse generators according the custom specific needs.

Dolv Electromechanic was chosen to represent Montena in Israel.

The list below shows some references of test systems according to MIL STD 461, MIL STD 188-125 and other military standards.

 

Mil STD Systems references 

Marx pulse generator 320 kV, rise time 5 ns / duration 80 ns with control unit  for NEMP test according to MIL STD 461 / RS105

NEMP test system according to MIL STD 461E – RS105 loading voltage 80 kV rise time 2.3 ns / duration 23 ns  with 1.8 m high radiation line

NEMP test system according to MIL STD 461E – RS105 Marx pulse generator 120 kV,  rise time 2.3 ns / duration 23 ns with 2.7 m high radiation line

 NEMP test system according to MIL STD 461E – RS105 Marx pulse generator 230 kV, rise time 2.3 ns / duration 23 ns  with 3.6 m high radiation line

NEMP test radiation for tests according to MIL STD 461E – RS105 Marx pulse generator 800 kV, rise time 2.3 ns / duration 23 ns with 9 m high radiation line

NEMP test system according to MIL STD 461E – RS105 Loading voltage 75 kV rise time 2.3 ns / duration 23 ns connected to a GTEM, 1m septum height

HV pulse generator 12kV, rise time 5 ns / duration 200 ns

High voltage pulse generator 80kV, rise time 5 ns / duration 500 ns for Pulse Current Injection (PCI) test according to MIL STD 188/125, appendix B (short pulse)

Marx pulse generator 350 kV, rise time 5 ns / duration 500 ns with control unit for Pulse Current Injection according to MIL STD 188/125, short pulse

Pulse generator 3 kV, rise time 0.6 μs / duration 3.4 ms for Pulse Current Injection according to MIL STD 188/125, intermediate pulse

Variable pulse length generator 25 kV, rise time < 5 ns for Pulse Current Injection test according to MIL STD 188/125

Square pulse generator for immunity test according to MIL STD 461 / CS115

Damped Sinusoidal pulse generator for immunity test according to MIL STD 461 / CS116

HIRA antenna Half impulse radiating antenna for the generation UWB E-field pulses (Ultra Wide Band pulses with sub nanosecond pulse duration)

ESD 300kV and P-static test system for helicopter and airborne system