Frankonia SAC-3 Plus
Semi Anechoic 3m EMC Chamber with dome-shape design
Overview | SAC-3 Plus |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3m |
Volume | up to ø2,0 m |
Special | Performance dome shape design |
The SAC-3 Plus is Frankonia’s most versatile full compliant EMC testing solution at 3,0 m measuring distance with a Quiet Zone (QZ) up to ø2,0 m. It is adapted for full compliant emission and immunity testing. The innovatively shaped roof, called dome design, with its optimized absorber layout leads to minimized reflections and offers outstanding performance for NSA, SVSWR and FU.
Features
• Cost-efficient and high-performance solution for a 3,0 m measuring distance
• Full compliant EMI/EMS
• Adapted steel structure and optimized RF-shielding with dome-shaped roof
• Upgradeable for E-Drive (load machine, BlueBox, battery test system)
• Ingenious absorber lining with Frankosorb®
• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers
• Turnkey solution
Typical Product Standards
Emission
• CISPR 11
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11452
• MIL-STD 461
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
• IEC/EN 61000-4-3
Immunity
• IEC/EN 61000-4-3
Typical Specifications
Chamber Type |
SAC-3 Plus S |
SAC-3 Plus M |
SAC-3 Plus L |
SAC-3 Plus |
External dimension |
8.480 x 6.530 x 6.000 mm (LxWxH) |
8.780 x 6.530 x 6.000 mm (LxWxH) |
9.230 x 6.530 x 6.000 mm (LxWxH) |
9.680 x 6.530 x 6.000 mm (LxWxH) |
Quiet Zone |
ø1,2 m |
ø1,5 m |
ø2,0 m |
ø2,0 m |
Load capacity |
up to 5,0 tons; special turntable systems possible |
|||
Frequency range |
9 kHz/ 26 MHz to 18 GHz (option 40 GHz) |
Performance & Compliance – Semi Configuration
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed