Frankonia SAC-10 Plus Semi Anechoic 10m EMC Chamber in Compact shape
Overview | Frankonia SAC-10 Plus |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0 m, 5,0 m and 10,0 m |
Volume | up tp ø3,0 m |
Special | Compact 10 m chamber |
The SAC-10 Plus is Frankonia’s full compliant and state-of-the-art EMC testing solution at 10m, 5m & 3m measuring distances with a Quiet Zone (QZ) of ø4,0m. The innovative polygonal shape along with its optimized absorber layout is a space-saving, cost-saving and efficient solution with a single test axis. The SAC-10 Plus is fully compliant for emission tests validated according to CISPR 16-1-4, as well as full compliant for immunity tests according to IEC/EN 61000-4-3. In addition, the SAC-10 Plus is Frankonia’s most compact 10m chamber available to meet CISPR 16-1-4 and ANSI C63.4 test site requirements.
Features
• 10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m or ø4,0 m
• Full compliant EMI/EMS
• Ingenious absorber lining with Frankosorb®
• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers
• Cost-saving and future-proof investment Space-saving chamber in polygonal shape
• Turnkey solution
Typical Product Standards
Emission
• CISPR 11
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11452
• MIL-STD 461
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
Immunity
• IEC/EN 61000-4-3
Typical Specifications
Chamber | SAC-10 Plus |
External dimensions | 19.205 x 12.080 x 8.325 mm (LxWxH) |
Version | Polygonal shape design with single test axis |
Quiet Zone | ø3,0 m or ø4,0 m |
Turntable | ø3,0 m or ø4,0 m |
Measuring distances | 10,0 m, 5,0 m and 3,0 m |
Load capacity | up to 5,0 tons; special turntable systems possible |
Frequency range | 9 kHz/ 30 MHz to 18 GHz (option 40 GHz) |
Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed