Frankonia MIL-STD Chamber advanced Military Testing Chamber for Vehicles and large EUT’s
Overview | MIL-STD Chamber advanced |
EMI | MIL-STD 461 / DO-160 |
EMS | MIL-STD 461 / DO-160 |
Test distance | 1,0 m |
Volume | No test volume |
EMI Advanced | CISPR 16-1-4 and ANSI C63.4 |
EMS Advanced | IEC/EN 61000-4-3 |
Test distance | up to 10,0 m |
Volume | e.g. ø6,0 m |
Special | Adapted to any EUT type and size |
Frankonia’s long pyramid absorbers offer the possibility to combine MIL-STD 461 test requirements with commercial test requirements according to CISPR 16-1-4 and ANSI C63.4, as well as a combination of automotive component and vehicle tests is possible. Frankonia’s expertise in turnkey projects and the ability to provide solutions fully adapted to customers’ demands allows especially military testing of heavyweight and large EUT’s.
Features
• High performance solution for military testing
• Various testing possibilities in the combination of commercial, automotive and military
• Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
• Full compliant EMI/EMS
• Highly customizable solution for any kind of EMC testing and limitless integration of individual applications
• Adjustable chamber size, characteristics and configuration due to different EUT requirements
• Turnkey solution
Typical Product Standards
Emission
• CISPR 11
• CISPR 12
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11451
• ISO 11452
• MIL-STD 461
• RS 101, RS102, RS103
• ECE R10.5
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
Immunity
• IEC/EN 61000-4-3
Chamber | MIL-STD Chamber Advanced |
Size | To be defined acc. to EUT type and size |
Measuring distances | 1,0 m (Mil-STD 461); up to 10,0m for commercial applications |
Load capacity | up to 80,0 tons; special turntable systems and integrations possible |
Frequency range | 9 kHz/ 26 MHz to 40 GHz |
Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3 Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
• Full compliant emission (EMI) according to MIL-STD 461 and DO-160
• Full compliant immunity (EMS) according to MIL-STD 461 and DO-160
• Absorption at normal incidence: 80 MHz to 250 MHz ≥ 6 dB, as per standard requirements above 250 MHz ≥ 10 dB, as per standard requirements