חיפוש
סגור את תיבת החיפוש

FRANKONIA – ACTC – SAC – 10VX Anechoic Chambers

Frankonia SAC-10Vx Next generation multi-purpose Anechoic Chambers

Overview Frankonia SAC-10Vx
EMI CISPR 16-1-4 and ANSI C63.4, full compliant

CISPR 25 and CISPR 12, full compliant

EMS IEC/EN 61000-4-3, full compliant
Test distance up to 10m
Volume e.g. ø6,0 m
Special Optimized for V2V and V2I measurents
ECE R10.5 Full complient at 10m with dynamometer

The SAC-10Vx chamber is Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance dedicated to automotive full vehicle tests offering an integrated emission free dynamometer. Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emission and immunity testing. The SAC-10Vx meets ECE R10.5 criteria’s and offers the possibility to test vehicle communications and infrastructure tests.

Features

• Optimized for Vehicle-2-Vehicle and Vehicle-2-Infrastructure tests

• Testing according to ECE R10.5 with an integrated dynamometer

• Full compliant EMI/EMS with Frankosorb® Absorbers

• Highly customizable solution for any kind of EMC testing and limitless integration of individual applications

• Adjustable chamber size, characteristics and configuration due to different EUT requirements

• Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)

• Specialized for ‘out-of-the-range’ EMC test environments

• Turnkey solution

Special Features

• The SAC-10Vx works as a regular EMC chamber with an integrated dynamometer, customized for passenger vehicles or trucks

• The chamber is large enough to accommodate a second turntable to position a second vehicle at 10m distance, or to integrate a heavy load area for heavy-duty vehicles

• The optimized absorber lining with Frankosorb® technology improves the performance in the low frequency from 9 kHz up to 6 GHz for the main applications, and also offers a wide-span range up to 40 GHz Capability to test today’s and future technologies that are related to autonomous driving, wireless communications, IoT, Vehicle-2-Vehicle and Vehicle-2-Infrastructure dedicated to real testing (e.g. GPS, 4G, 5G, Wi-Fi, Lidar, Radar, Ultrasonic, eCall, TPMS, …)

• Possibility to integrate a mobile arch system for antenna measurements (Spherical Near-field, 400 MHz to 6 GHz)

Typical Product Standards

Emission

• CISPR 11

• CISPR 12

• CISPR 14

• CISPR 15

• CISPR 25

• CISPR 32

• MIL-STD 461

• ECE R10.5

Immunity

• IEC/EN 61000-4-3

• ISO 11451

• ISO 11452

• MIL-STD 461

• RS 101, RS102 RS103

• ECE R10.5

Typical Verification Standards

Emission

• CISPR 16-1-4 and/or ANSI C63.4

Immunity

• IEC/EN 61000-4-3

Performance & Compliance

• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4 Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3 Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

• Full compliant emission (EMI) according to CISPR 25 Ed.4 (ALSE verification acc. to the long-wire method recommended)

• Full compliant emission (EMI) according to CISPR 12 at 3,0 m

• Full compliant immunity (EMS) according to ISO 11452 and ISO 11451

• Perfectly meets ECE R10.5 with dynamometer integration

 

Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Interfaces for Franikonia Anechoic Chambers Data Sheet