FRANKONIA – SAC-3 / FAC-3 Transformers

Frankonia SAC-3 / FAC-3 Transformer Semi and Fully Anechoic 3m EMC Chamber transformable combination
Overview SAC-3 / FAC-3 Transformer
EMI CISPR 16-1-4 and ANSI C63.4, full compliant
EMS IEC/EN 61000-4-3, full compliant
Test distance 3m
Volume ø2,0 m as SAC Chamber

ø1,5 m as FAC Chamber

Special Transformable test site from SAC to FAC

The SAC-3/FAC-3 Transformer is Frankonia’s full compliant EMC testing solution at 3,0m measuring distance offering semi as well as fully conditions. The SAC configuration provides a Quiet Zone (QZ) of ø2,0m and is compliant with CISPR 16-1-4 as well as ANSI C63.4. The FAC configuration provides a Quiet Zone (QZ) of ø1,5m and is compliant with CISPR 16-1-4 as well as IEC/EN 61000-4-22. The SAC-3/FAC-3 Transformer chamber is adapted for full compliant emissions and immunity testing with a traditional square design.

 

Features

• Transformable from SAC to FAC test site

• Cost-effective solution combining an SAC with an FAC chamber

• High-performance for a 3,0 m measuring distance

• Full compliant EMI/EMS

• Adapted steel structure and optimized RF-shielding with dome-shaped roof

• Ingenious absorber lining with Frankosorb®

• Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

• Turnkey solution

Typical Product Standards

Emission

• CISPR 11

• CISPR 14

• CISPR 15

• CISPR 25

• CISPR 32

• MIL-STD 461

Immunity

• IEC/EN 61000-4-3

• ISO 11452

• MIL-STD 461

Typical Verification Standards

Emission

• CISPR 16-1-4 and/or ANSI C63.4

• IEC/EN 61000-4-22

Immunity

• IEC/EN 61000-4-3

• IEC/EN 61000-4-22

 

Typical Specifications

Chamber SAC-3 / FAC-3 Transformers
External dimensions 9.680 x 6.530 x 6.000 mm (LxWxH)
Quiet Zone ø2,0 m; height 1,5 m (SAC)

ø1,5 m; height 1,5 m (FAC)

Quiet Zone IEC/EN 61000-4-22 ø1,5 m; height 1,5 m (30 MHz -1 GHz)

ø1,0 m; height 1,0 m (1 GHz -6 GHz)

Measuring distances 3,0 m
Load capacity up to 5,0 tons; special turntable systems possible
Frequency range 9 kHz/ 26 MHz to 18 GHz (option 40 GHz)

 

Performance & Compliance – Semi Configuration

• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

 

Performance & Compliance – Fully Configuration

• Full compliant emission (EMI) according to CISPR 16-1-4

Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

• Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard Deviation SdB c ≤ 1,8 dB

 

Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Interfaces for Franikonia Anechoic Chambers Data Sheet