Frankonia’s compact hybrid chamber solution at 3.0 m measuring distance
The CHC is Frankonia’s optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3.0 m measuring distance. The most important advantage of the CHC is the upgradability from semi-anechoic chamber with ground plane to fully anechoic chamber with absorbers on the ground.
| CHC | |
| Technical specification | |
| External dimension (L x W x H) | 7.355 m x 3.755 m x 3.300 m |
| Frequency range | 30 MHz to 18 GHz (option 40 GHz) |
| Absorber lining | |
| Walls and ceiling | Full lining with ferrite absorbers; partial lining with Frankosorb® hybrid absorbers H450 |
| Floor | Movable hybrid absorbers between antenna and EUT; optional configuration for fully anechoic chamber |
| CHC – Performance | |
| Emission test (EMI) | Pre-compliance by the method CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, CISPR 32 (semi-configuration) |
| Measuring distance | 3.0 m |
| Chamber validation | According to CISPR 16-1-4 |
| Quiet zone (semi configuration) | ∅ 1.2 m; height 2.0 m |
| Quiet zone (fully configuration) | ∅ 1.2 m; height 1.0 m |
| Immunity test (EMS) | Full compliance according to IEC/EN 61000-4-3 |
| Uniform area | 1.5 m x 1.5 m |
| Measuring distance | 3.0 m |
| Chamber validation | According to IEC/EN 61000-4-3 |
| Deviation FU (80 MHz to 18 GHz) | 0 dB /+6 dB at 75 % of 16 measuring points |
Features
- Radiated emissions (EMI): Pre-compliance by the methods of CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, and CISPR 32 (semi configuration)
- Radiated immunity (EMS): Compliance according to IEC/EN 61000-4-3
- Compact chamber design and adapted hybrid absorber lining with Frankosorb®
- Upgradability to a fully anechoic chamber
∗Turnkey solution