The SAC-10 Plus Triton Class for EMC testing is a revolution in its class. The benefits of its triple test axes allow our customers to measure all required EMI/EMS procedures without the need to modify the test environment or the test setup. This also includes the test equipment and instruments that can remain connected in the chamber. The antenna and absorber area for each procedure specifically moves to the test scenario either in manual, semi-automatized or fully automatized mode controlled by Frankonia software. Thus, the quality of EMC testing remains at a constantly high level, the testing time decreases, and malfunction and damage is almost impossible. The frequency range of the all-new SAC-10 Plus is from 30 MHz to 18 GHz (40 GHz as option) and it offers outstanding performance for NSA, SVSWR and FU.
SAC-10 Plus – Hybrid Chamber | |
Technical specification | |
External dimension (L x W x H) | 19.205 m x 12.080 m x 8.325 m (polygonal shape) |
Turntable | ∅ 3.0 m with a load of 2.0 tons or 3.0 tons |
Frequency range | 30 MHz to 18 GHz (option 40 GHz) |
Absorber lining | |
Walls and ceiling | Partial lining with ferrite absorbers; mix of long and short Frankosorb® pyramid/hybrid absorbers |
Floor | Sliding absorber area for immunity and emission test, individual configured for each test axis |
Standard configuration and options
- Standard: Customized SAC-10 Plus prepared for manual absorber and antenna movement
- Option 1: Customized SAC-10 Plus prepared for semi-automatized absorber and antenna movement
- Option 2: Customized SAC-10 Plus prepared for fully automatized absorber and antenna movement
SAC-10 Plus – Performance per test axis | |
Test axis 1 – EMI | |
Emission test (EMI) | Full compliance according to CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, and CISPR 32 |
Quiet zone | ∅ 3.0 m; height 2.0 m |
Measuring distance | 10.0 m & 3.0 m |
Chamber validation | According to CISPR 16-1-4 and ANSI C63.4 |
Deviation NSA at 10.0 m (30 MHz to 1 GHz) | ±3.5 dB (30 MHz to 80 MHz), ±3.0 dB (80 MHz to 200 MHz) and ±2.0 dB (200 MHz to 1 GHz) |
Deviation NSA at 3.0 m (30 MHz to 1 GHz) | ±2.5 dB (30 MHz to 80 MHz), ±2.0 dB (80 MHz to 200 MHz) and ±1.5 dB (200 MHz to 1 GHz) |
Test axis 2 – EMI | |
Emission test (EMI) | Full compliance according to CISPR 11, CISPR 16-2-3, CISPR 22 and CISPR 32 |
Quiet zone | ∅ 3.0 m; height 2.0 m |
Measuring distance | 3.0 m |
Chamber validation | According to CISPR 16-1-4 |
Deviation SVSWR (1 GHz to 18 GHz) | +5 dB (1 GHz to 18 GHz) |
Test axis 2 – EMS | |
Immunity test (EMS) | Full compliance according to IEC/EN 61000-4-3 |
Uniform area | 1.5 m x 1.5 m |
Measuring distance | 3.0 m |
Chamber validation | According to IEC/EN 61000-4-3 |
Deviation FU (1 GHz to 18 GHz) | 0 dB/+6 dB at 100 % of 16 measuring points |
Test axis 3 – EMS | |
Immunity test (EMS) | Full compliance according to IEC/EN 61000-4-3 |
Uniform area | 1.5 m x 1.5 m |
Measuring distance | 3.0 m |
Chamber validation | According to IEC/EN 61000-4-3 |
Deviation FU (80 MHz to 1 GHz) | 0 dB/+6 dB at 100 % of 16 measuring points |
Special versions
- CISPR 12 & CISPR 25: The SAC-10 Plus offers the possibility to be used for vehicle and components tests according to CISPR 12 and CISPR 25.
Features
- Radiated emissions (EMI): Full compliance according to CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, CISPR 32
- Radiated immunity (EMS): Full compliance according to IEC/EN 61000-4-3
- Compact chamber design with adapted steel structure and optimized RF-shielding in polygonal shape
- Advanced absorber lining with Frankosorb® long-lasting absorbers (Frankonia technology)
- Efficient and economic test site conditions
- Reproducible test procedures at a constant high-performance level
- Time saving – no need to modify the test setup
- Manual, semi-automatic, or fully automatized absorber and antenna movement
- Turnkey solution