Frankonia’s full compliant and customizable EMC testing solution at 10.0 m measuring distance
The SAC-10 is Frankonia’s most versatile fully compliant EMC solution at 10.0 m measuring distance. Due to the high grade of customization that reflects our customers’ demand, the semi-anechoic chamber is adaptable in any dimension and offers several quiet zones, for instance, ∅ 2.0 m up to ∅ 5.0 m or even larger. The innovative concept with its impressionable absorber layout achieves exceptional performance for emissions and immunity testing and superior minimized reflections.
The fully customizable SAC-10 covers all requirements in today’s and future EMC testing environments, without any difference between EUTs that belong to the road, water or air. Putting specific customers’ demand into practice and the integration of individual applications is without limitation due to our highly specialized and adjustable solution. Furthermore, the chamber is designed for EMC components and complete system testing for all kinds of combustion, hybrid, fuel cell and e-drive system. The frequency range of the SAC-10 is from 30 MHz to 18 GHz (40 GHz as option) and offers magnificent performance for NSA, SVSWR and FU.
SAC-10 | ||||
Technical specification | ||||
Chamber type* | SAC-10-2 | SAC-10-3 | SAC-10-4 | SAC-10-5 |
External dimension (L x W x H) | 21.080 m x 13.730 m x 8.550 m | 21.680 m x 13.730 m x 8.550 m | 22.580 m x 15.980 m x 9.000 m | 23.480 m x 16.580 m x 9.000 m |
Absorber configuration | Frankosorb® long pyramid absorbers, or as hybrid configuration to reduce the external dimension | |||
Turntable | ∅ 2.0 m | ∅ 3.0 m | ∅ 4.0 m | ∅ 5.0 m |
Load capacity | Range from 0.3 tons up to 80.0 tons | |||
Frequency range | 30 MHz to 18 GHz (option 40 GHz) | |||
Absorber lining | ||||
Walls and ceiling | Optimized lining with Frankosorb® pyramid absorbers P2200 and P2400, or as a hybrid configuration with Frankosorb® hybrid absorbers H1000 in case of building size limitations | |||
Floor | Moveable Frankosorb® hybrid absorbers H600 for immunity tests, and pyramid absorbers P450 for emission tests |
*Chamber type and size adjustable according to customers’ specific requirements
SAC-10 – Performance | ||||
Emission test (EMI) | Full compliance according to CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, and CISPR 32 | |||
Quiet zone | ∅ 2.0 m; height 2.0 m | ∅ 3.0 m; height 2.0 m | ∅ 4.0 m; height 2.0 m | ∅ 5.0 m; height 2.0 m |
Measuring distance | 10.0 & 3.0 m | |||
Chamber validation | According to CISPR 16-1-4 and ANSI C63.4 | |||
Deviation NSA (30 MHz to 1 GHz) | ±3.5 dB | |||
Deviation SVSWR (1 GHz to 18 GHz) | +6.0 dB | |||
Immunity test (EMS) | Full compliance according to IEC/EN 61000-4-3 | |||
Uniform area | 1.5 m x 1.5 m | |||
Measuring distance | 3.0 m | |||
Chamber validation | According to IEC/EN 61000-4-3 | |||
Deviation FU (80 MHz to 18 GHz) | 0 dB / +6 dB at 75 % of 16 measuring points |
Special versions
- Hybrid configuration: In case of building size limitations and the renounce of the advantages of long pyramid absorbers, all SAC-10 chambers can be configured as a hybrid solution.
- CISPR 12 & CISPR 25: The SAC-10 offers the possibility to be used for vehicle and components tests according to CISPR 12 and CISPR 25.
Features
- Radiated emissions (EMI): Full compliance according to CISPR 11, CISPR 14-1, CISPR 16-2-3, CISPR 22, and CISPR 32
- Radiated immunity (EMS): Full compliance according to IEC/EN 61000-4-3
- Highly customizable solution for any kind of EMC testing
- Limitless integration of individual applications
- Adjustable chamber size, characteristic and configuration due to different EUT requirements
- Advanced absorber lining with Frankosorb® long-lasting absorbers (Frankonia technology)
- Available with long pyramid absorbers or with hybrid absorbers
- Specialized for ‘out-of-the-range’ EMC test environments
- Turnkey solution