Frankonia’s ultra compact chamber solution at 1.0 m measuring distance
The UCC is Frankonia’s alternative solution to the GTEM cell for pre-compliance testing as well as for research and science purposes. The most important advantages of the UCC is that the test engineer is able to enter the chamber, which allows for an easier, better and even larger EUT setup. The ultra compact chamber solution is designed for pre-compliance radiated emission and immunity tests, conducted tests, and pre-compliance tests for automotive components by the CISPR 25 method.
UCC | |
Technical specification | |
External dimension (L x W x H) | 4.280 m x 3.080 m x 2.550 m |
Frequency range | 150 kHz to 18 GHz (option 40 GHz) |
Absorber lining | |
Walls and ceiling | Full lining with ferrite absorbers; partial lining with Frankosorb® hybrid absorbers HF300 |
Floor | Movable ferrite absorbers between antenna and EUT |
UCC – Performance | |
Emission test (EMI) | Pre-compliance by the CISPR 25 method |
Measuring distance | 1.0 m |
Immunity test (EMS) | Pre-compliance by the method IEC/EN 61000-4-3 and DIN/ISO 11452-2 |
Uniform area | 0.5 m x 0.5 m |
Measuring distance | 1.0 m |
Deviation FU (80 MHz to 18 GHz) | 0 dB/+6 dB at 100 % of 4 measuring points |
Features
- Alternative to GTEM cell
- Radiated emissions (EMI): Pre-compliance by the CISPR 25 method
- Radiated immunity (EMS): Pre-compliance by the IEC/EN 61000-4-3 and DIN/ISO 11452-2 metho
- Compact chamber design and adapted hybrid absorber lining with Frankosorb
Turnkey solution