Skip to content
הלוחמים 53, חולון
1800-800-552
info@dolevltd.co.il
Homepage
Magnetic shielding solution
Limitation of magnetic fields
Radiation from high voltage lines, active shielding
Electrical pollution
3-axis electromagnetic radiation meter
WIFI at school
The relationship between electromagnetic fields and cancer
Is solar electricity production free from electromagnetic radiation?
Urban renewal in Israel – Tama 38 TMA 38/1, TMA 38/2
Active limitation system of magnetic fields
Radiation tests
Electromagnetic compatibility EMC,RF,EMP
cyber-Information leakage, and electromagnetic interference in a DC data center
Data Center
EMC shielding solutions for labs & chambers
RFI shielded doors /EMI
MRI-EEG rooms
EMC filters
Montena company Test Equipment EMC
Frankonia company Test Equipment EMC
HEMP High-altitude electromagnetic pulse
EMP test equipment
HEMP solutions
Portable PCI test system
EMP / NEMP protectors
About
Companies represented
Certificates and approvals
Companies represented
Contact us
Homepage
Magnetic shielding solution
Limitation of magnetic fields
Radiation from high voltage lines, active shielding
Electrical pollution
3-axis electromagnetic radiation meter
WIFI at school
The relationship between electromagnetic fields and cancer
Is solar electricity production free from electromagnetic radiation?
Urban renewal in Israel – Tama 38 TMA 38/1, TMA 38/2
Active limitation system of magnetic fields
Radiation tests
Electromagnetic compatibility EMC,RF,EMP
cyber-Information leakage, and electromagnetic interference in a DC data center
Data Center
EMC shielding solutions for labs & chambers
RFI shielded doors /EMI
MRI-EEG rooms
EMC filters
Montena company Test Equipment EMC
Frankonia company Test Equipment EMC
HEMP High-altitude electromagnetic pulse
EMP test equipment
HEMP solutions
Portable PCI test system
EMP / NEMP protectors
About
Companies represented
Certificates and approvals
Companies represented
Contact us
Search
SPECIFICATIONS - DATASHEETS
PG-DCS05B-100A
Transient susceptibility generator, for DCS05.B, switching simulation and NEMP simulation for All Land and Sea Services levels
Up to 100 A into 10 ohm, 9 freq.: 0.5, 1, 2, 3, 5, 10, 15, 35 and 50 MHz
PG-DCS05B-9
Transient susceptibility generator, for DCS05.B, switching simulation and NEMP simulation for Sea Services – Below Decks levels
Up to 25 A into 10 ohm, 9 freq: 0.5, 1, 2, 3, 5, 10, 15, 35 and 50 MHz
PG-DCS05B-15
Transient susceptibility generator, for DCS05.B (Sea Services – Below Decks) and MIL-STD 461 D/E/F/G CS116
15 freq: 0.01, 0.03, 0.1, 0.3, 0.5, 1, 2, 3, 5, 10, 15, 30, 35, 50 and 100 MHz Up to 25 A into 10 ohm (DCS05.B) Up to 10 A into 100 ohm (CS116)
PG-DCS06B-DCS12B
Transient susceptibility generator, for DCS06.B and DCS12.B
100 kHz (DCS06.B), 15.9 kHz (0.15 ohm, DCS12.B), 15.9 kHz (0.4 ohm, DCS12.B), 10.9 kHz (2.5 ohm, DCS12.B)