The FAC-3 is Frankonia’s solution for a fully compliant chamber at 3.0 m measuring distance under free-space conditions. The fully anechoic chamber is designed according to CISPR 16-1-4 as a test site without a ground plane. Without reflections from the floor, a height scan is no longer necessary and measuring time decreases. With its specific requirements for the test site, Frankonia’s FAC-3 is supremely prepared to meet our customers’ demands.

FAC-3
Technical specification
External dimension (L x W x H) 8.705 m x 4.655 m x 3.750 m
Turntable ∅ 1.5 m with a load of 500 kg
Frequency range 30 MHz to 18 GHz (option 40 GHz)
Absorber lining
Walls and ceiling Full lining with ferrite absorbers; partial lining with Frankosorb® hybrid absorbers H600
Floor Full lining with ferrite absorbers; partial lining with moveable Frankosorb® hybrid absorbers H600
FAC-3 – Performance
Emission test (EMI) Full compliance according to CISPR 16-2-3
Quiet zone ∅ 1.5 m; height 1.5 m
Measuring distance 3.0 m
Chamber validation According to CISPR 16-1-4
Deviation FSNSA (30 MHz to 1 GHz) ±4.0 dB
Deviation SVSWR (1 GHz to 18 GHz) +6.0 dB
Immunity test (EMS) Full compliance according to IEC/EN 61000-4-3
Uniform area 1.5 m x 1.5 m
Measuring distance 3.0 m
Chamber validation According to IEC/EN 61000-4-3
Deviation FU (80 MHz to 18 GHz) 0 dB/+6 dB at 75 % of 16 measuring points

Features

  • Radiated emissions (EMI): Full compliance according to CISPR 16-2-3
  • Radiated immunity (EMS): Full compliance according to IEC/EN 61000-4-3
  • Customizable and compact chamber design
  • Optimized absorber lining with Frankosorb® long-lasting absorbers (Frankonia technology)